ThermoTST HTS280 is a precise Temperature Forcing Systems with a wider temperature range from normal temperature (inlet temperature) to+280 ℃, providing a very advanced temperature conversion test capability. Temperature conversion from normal temperature to+125 ℃ for about 10 seconds; It meets the requirements of various production environments and engineering environments through long-term multi-condition verification.
Features
Fast temperature change rate, about 10 seconds from normal temperature to+125 ℃
Effective temperature range, normal temperature (intake temperature) to+280 ℃
Compact and mobile design
Touch screen operation, human-computer interface
Fast DUT temperature stabilization time
Temperature control accuracy ± 1 ℃, display accuracy ± 0.1 ℃
Air flow can be up to 18SCFM
Defrost design, quickly remove the internal moisture accumulation
Application
Characteristic analysis, high and low temperature change test,
temperature impact test, failure analysis and other reliability tests, such
as:Chips, microelectronics, integrated circuits(SOC, FPGA, PLD, MCU,
ADC/DAC, DSP, etc.)Flash, UFS, eMMC PCBs, MCMs, MEMS, IGBT,
sensors, small module componentsOptical communication (e.g.
Transceiver high and low temperature testing, SFP optical module high
and low temperature testing, etc.)Other electronic industry, aerospace new
materials, laboratory research
Test standard
Meet the U.S. military standard MIL system test standards
Meet the domestic military component GJB system test standard
Meet JEDEC test requirements
Specifications
Temperature Range | Normal temperature (intake temperature) to+280 º C |
Typical Temperature Transition Rate | Normal temperature to+125 º C for about 10 seconds |
Temperature Accuracy | ± 1 ºC |
System Airflow Output | 4 ~ 18 SCFM(1.9L/s ~ 8.5L/s) |